HIGH VOLTAGE BREAKDOWN TESTER
MODEL : HV-55

Features
- Minimum manual operation of controls to carry out tests. High degree of repeatability and very safe to use
- Test On/Off/Reset control on single switch. Design incorporates motor controlled auto transformer. Instrument automatically applies test voltage from zero to set voltage and back to zero when test is over. (No manually operated variable auto transformer)
- Pre-set-able test voltage and maximum trip current
- Independent Meters indicate applied High Voltage and leakage current measurement
- Built in timer up to 60 seconds. Linear setting on potentiometer. Other timer range up to 15 minutes can be provided
- Specially designed High voltage test socket to adapt different test prods suitable to test needs
- Short Circuit Protected
Introduction
High Voltage Break Down Tester, Model HV-55 is designed to meet testing requirements of dielectric strength tests in various electrical gadgets, appliances, components and electrical insulating material used or manufactured in industries. Test can be carried out following simple initial setting of control i.e. required test voltage, maximum trip or leakage current and required test duration. Following these initial settings, operator can carry out High Voltage test without interaction with instrument controls (unless change in the settings is desired.) One single switch controls test On/Off /Reset function. Since the test parameters and their limits are set initially, repetitive tests can be carried out consistently eliminating human errors.
Instrument incorporates specially designed for High Voltage AC output and DC output and to leakage current. These test sockets are designed considering operators’ safety to electrical shock hazard. High voltage electrical contacts are deep inside the sockets to avoid inadvertent human contact. Test prods comprise of Teflon Cable covered with Silicon rubber sleeve and a connector that connects to instrument.
During testing, if the current through the specimen exceeds pre-set value as set on the Current Limit potentiometer, high Voltage Test is discontinued immediately while "TRIP" LED glows and sound annunciation is trigged. Equipment comprises of servo controlled Variable Auto Transformer for applying High Voltage to the device under test. This ensures long trouble free service of equipment. Carefully designed current sensing circuitry ensures accurate results of measurements. HV probes are designed using PVC insulating material having good electrical insulation properties.
Applications
Testing of Transformers, Capacitors, Electrical Insulating Oil, Electrical PVC Cables, Electrically operated Appliances, Power tools, etc.
Specifications
|
AC Output :
|
0 to 5 Kilo Volts
|
|
DC Output :
|
0 to 5 Kilo Volts
|
|
Accuracy :
|
± 5% both for AC and DC
|
|
Current Limit :
|
0 to 15 Milli Amp. Continuously adjustable on potentiometer provided on the front panel. Optional: Other current limit scale i.e. <30 mA can be provided.
|
|
Test Period :
|
Test period timer setting up to 60 Seconds, linear control with OFF switch.
|
|
Break Down Indicator :
|
Trip LED and Sound annunciation
|
|
Input Power :
|
210 to 250 Volts, 50 Hz.
|
|
Read Out :
|
Two 90 mm Moving Coil Meters for voltage and current measurement
|
|
Operating Environment :
|
5 to 55oC, R.H. < 90%. Non condensing
|
|
Design Incorporates :
|
- Epoxy potted heavy duty high voltage transformer for trouble free service
- High Voltage Prod and Sense Probe with switch
|
|
Dimension :
|
340 mm x 305 mm x 260 mm Height
|
|
Weight :
|
17.8 Kg. approx.
|