EMERGENCY CONDITION WARNING UNIT (SORTS)


Features

  • Fault tolerant design
  • Unit is protected from shorts in lamp circuit
  • Uses automatic resettable fuses
  • Precise and stable master blinker flashing frequency
  • Design uses component of proven technology
  • Parameter ratings selected to provide trouble free service

Specifications of Electronic card CWU-4 sorts LX-3

Specifications : Limits
Power supply voltage 18 to 32V DC
Signal voltage 15V to 32V
Annunciation Lamp power per channel 5W
Master Blinker operating Frequency 150 ± 15 counts/min.
Current consumption :
When no signals are produced 0.005A max.
When the KCU-1 button is engaged for acknowledge 0.5A max.
When annunciation indicating lamps are tested 3A max.
Insulation resistance under normal working condition
(Megger test voltage=100V DC)
≥ 100 Mega ohms
Weight of module CWU-4 160 grams max.